Table 2–2 (Cont.) SROM Memory Tests, CPU Jumper J1
Bank
# Test Description Test Results
5 Memory Test,
Cache Enabled:
Tests memory with
backup and data
cache enabled.
Test status displays on OCP:
12345.done.
If an error is detected, the bank number and failing
SIMM position are displayed. The following OCP message
indicates a failing SIMM at bank 0, SIMM position 2.
FAIL B:0 S:2
Test duration: Approximately 2 seconds per 8 megabytes
of memory.
Figure 2–2 shows the bank and SIMM layout for
AlphaServer 1000 systems. After determining the bad
SIMM, refer to Chapter 6 for instructions on replacing
FRUs.
Note: The memory tests do not test the ECC SIMMs. If
the operating system logs five or more single-bit correctible
errors, swap the suspected ECC SIMMs with good SIMMs
and repeat the memory test.
3 Backup Cache Test:
Tests backup cache
alternatively with
data cache enabled
then disabled.
Test status displays on OCP:
d 12345.done.
D 12345.done.
D 12345.done.
d 12345.done.
If an error is detected, the bank number and failing
SIMM position are displayed. The following OCP message
indicates a failing SIMM at bank 0, SIMM position 2.
FAIL B:0 S:2
Test duration: Approximately 2 seconds per 8 megabytes
of memory.
Figure 2–2 shows the bank and SIMM layout for
AlphaServer 1000 systems. After determining the bad
SIMM, refer to Chapter 6 for instructions on replacing
FRUs.
Note: The memory tests do not test the ECC SIMMs. If
the operating system logs five or more single-bit correctible
errors, swap the suspected ECC SIMMs with good SIMMs
and repeat the memory test.
Power-Up Diagnostics and Display 2–5