Table 1–1 Diagnostic Flow for Power Problems
Symptom Action
System does not power on.
Check the power source and power cord.
Check that the system’s top cover is properly
secured. A safety interlock switch shuts off power
to the system if the top cover is removed.
If there are two power supplies, make sure both
power supplies are plugged in.
Check the On/Off switch setting on the operator
control panel.
Check that the ambient room temperature is
within environmental specifications (10–40°C,
50–104°F).
Check that internal power supply cables are
plugged in at both the power supply and system
motherboard (Section 5.9).
Power supply shuts down after a
few seconds (fan failure).
Using a flashlight, look through the front (to the left
of the internal StorageWorks shelf) to determine if the
fans are spinning at power-up. A failure of either fan
causes the system to shut down after a few seconds.