Status Monitoring Using USM-A
6.11 USM (Universal Status Monitor),
continued
6.11.2 Serial Configuration
O
O
HEM
Power Supply Power Supply Power Supply
Power SupplyPower Supply
Polling Computer
(with Alpha Soft)
HUB
Cable Headend or Office
PSM
PSM
PSM
PSM
PSM
6. INSTALLATION
36
USM-A
The USM, used in conjunction with Alpha's status monitoring software, allows the
cable operator to remotely manipulate power supply functions, maintain precise data for
fault logs and direct service personnel to the exact nature of most malfunctions. Using the
simple and direct, menu-driven AlphaSoft program, vital power supply information such as
High and Low Battery Warnings, Battery Fail, Inverter ON, AC Main Fail and other critical
alarm conditions can be obtained instantaneously, thus greatly reducing overall operation
and maintenance costs.
Computer commands are converted into modulated radio frequency signals by the
HEM (Headend Modem) before being transmitted throughout the cable system. They are
received by the PSM (Power Supply Modem) located at each power supply location and
directed to the USM(-A) logic card. Power supply data is then re-transmitted back at sub-
low frequencies.
When faults are detected, the information is displayed on the terminal and written to a
dedicated file on the computers hard drive or printer. The system consists of:
XM Series Power Module
USM(-A) Logic Upgrade
RF Power Supply Modem (PSM)
RF Headend Modem (HEM)
Headend Computer (DOS compatible - 286 or higher)
AlphaSoft Status Monitoring Software
A segment of the information transmitted between the power supply and the computer
contains a binary address specific to each power supply in the system. The power supply
address must be set using DIP switches located on the USM (see setting chart and switch
location illustration on page 33). Each address must then be entered into the AlphaSoft
program for access by the polling computer. The PSM interface cable plugs into the serial
connector located on the USM card (see illustration on page 32).