Alpha 2000 Operations Instructions Page 27

  • Download
  • Add to my manuals
  • Print
  • Page
    / 33
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
The door "closes" completely and
then immediately re-opens by itself
to the "full-open" position.
SYMPTOM 21 :-
SOLUTIONS 20 :-
SYMPTOM 20 :-
The Operator works but fails to
respond to any obstruction which is in
it's way.
Operator will not "Reverse" if
obstructed whilst in the closing
mode, i.e. the automatic "Safety
Reverse" is not functioning.
Operator will not "Stop" if
obstructed whilst in the opening
mode, i.e. the automatic "Safety
Stop" is not functioning.
SOLUTIONS 21 :-
20.1 Check that the Travel Limit Switch
Wires are properly inserted into the Limit
Switch Terminals.
20.2 The Travel Limit Switch Brackets may
be loose and have moved. Set them in the
correct position and secure in place.
20.3 The PC Control Board may be faulty.
21.1 Check the manual operation of the door.
21.2 The door must be properly balanced
and in good working order.
21.3 Inspect the door for faulty or damaged
parts.
21.4 Check the Over-load Sensor settings of
the door operator.
MAN 01 - page 26
TROUBLE SHOOTING GUIDE
( Section 13 continued )
If you are in any doubt
whatsoever as to what the
problem might be or what is
causing it, call in the services
of a professional door
technician.
G a r a g e d o o r s , i f n o t
maintained in good working
order, or if not serviced
correctly, can be dangerous !
Rather than risk unnecessary
injury or damage to property,
have them serviced regularly
by a suitably qualified and
equipped door technician !