Alpha 2000 Operations Instructions Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 33
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
Operator "runs a short distance in the
"Opening" direction then stops
completely for no apparent reason.
SYMPTOM 7 :-
SOLUTIONS 7 :-
Check the "UP" Overload Sensor. The "UP"
sensitivity may be set to be too sensitive.
Increase the "opening force" by moving the
Sensor Adjustment Lever one notch at a
time as indicated on the PC Board.
SYMPTOM 8 :-
Operator works from the Wall Push-
button, but not from the remote
Transmitter.
Operator works in one direction only.
Door "opens", but will not "close".
Door "closes", but will not "open".
SYMPTOM 5 :-
SOLUTIONS 5 :-
SOLUTIONS 6 :-
Check the “Down" Overload Sensor. The
"Down" sensitivity may be set to be too
sensitive.
Increase the "closing force" by moving
Sensor Adjustment Lever "one notch at a
time" as indicated on the PC Board.
Operator "runs" a short distance in the
"closing" direction", then stops for no
apparent reason and then reverses it's
direction, "runs" a short distance again
then stops completely.
SYMPTOM 6 :-
SOLUTIONS 8 :-
8.1 Check the Battery in the Transmitter.
Replace the battery at least every 6
months.
Keep a spare Transmitter in a safe
place for use in an emergency !
8.2 Check that the codes of both the
Transmitter and the Receiver are
identical to each other.
8.3 Check that the wires from the Receiver
to the operator are properly connected.
8.4 Check that the Transmitter is working
correctly.
8.5 Check that the Receiver is functioning
correctly.
TROUBLE SHOOTING GUIDE
( Section 13 continued )
Operator works but the Courtesy Light
does not switch "ON".
SYMPTOM 9 :-
SYMPTOM 10 :-
SOLUTIONS 10 :-
Operator works from the "Transmitter"
but not from the "Wall Push-button"
SOLUTIONS 9 :-
9.1 Inspect the Wall Push-Button Console
for damage.
9.2 Inspect the Push-Button Wires for
damage and proper connections to the
operator.
10.1 Check the Lamp and replace if
necessary.
10.2 Check the P.C. Control Board and
replace if necessary.
5.1 Check the Travel Limit Switches for
damage.
5.2 Inspect the limit switch wires for
damage.
MAN 01 - page 23
Version 5
Page view 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 32 33

Comments to this Manuals

No comments