Proper Alignment
4. Install new carbon brush with the proper alignment of the brush holder followed by the
cap as shown in Figure 25.
Figure-25
Old Carbon Brush
worn down to a quarter
of an inch (1/4”).
New Carbon Brush
Figure-24
3. Check the carbon brush for wear. Replace if worn down to a 1/4" or if spring is
damaged.