Alpha 3000 Specifications Page 1

Browse online or download Specifications for Power supply units Alpha 3000. Alpha 3000 Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 91
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
BA
Operating Manual
for Testing Machine
ALPHA 3-3000
Deckblatt extern-e.ofm - 1.1 - 10/2004
DELTA 5-200
Page view 0
1 2 3 4 5 6 ... 90 91

Summary of Contents

Page 1 - DELTA 5-200

BAOperating Manualfor Testing MachineALPHA 3-3000 Deckblatt extern-e.ofm - 1.1 - 10/2004DELTA 5-200

Page 2

BAIn the operating manual we have marked the functions which may have any risk for the operator or the machine with the below mentioned signa

Page 3

BABefore startingBefore starting the machine please check and ensure that•only authorized staff is in the working range of the ma-chine•nobody ca

Page 4

BAClamping tools hydraulic / pneumaticDo not put your hands between the clamping jaws! Please always use a pair of tongs for placing the specime

Page 5 - Foreword

BAMaintenanceDuring the maintenance of the machine please observe the fol-lowing points in order to avoid serious injuries or machine dam-ages:•Keep t

Page 6 - Designated Use

BAWorks on the electrical equipmentIf an electrical connection is designated the testing machine or the control console has to be connected only by an

Page 7 - Duty to Exercise Diligence

BAThe legal duties of waste avoidance, waste disposal and recyc-ling have to be ful lled while working on or with the machine!Especially while instal

Page 8 - Operating Staff

BA Additional InformationIMPORTANTIt is important that the machine is installed in a room with a room temperature between + 16°C and +20°C in orde

Page 9 - Working Place and Symbolism

BA Maintenance RecommendationAt delivery the oil tank is  lled with the required hydraulic oil.We recommend an oil change every two years.The oil cha

Page 10

BA Recommendation for LubricantsWe recommend the use of the following lubricants:AGIPOSO 68ARALVITAMGF 68 VITAMDE 68BPENERGOL HLP 68 HLP 46SCHEVRO

Page 11 - Safety Precautions

IN Checkup and Acceptance of the DeliveryThe consignment has to be checked concerning external dama-ges immediately on receipt. If the packing is in p

Page 12

Register-e.ofm - 1.0 - 05/2004 Basic informations 1 Setup and installation 2 Operating manual machine 3 Operating manual software 4 Operating manual P

Page 13

IN Transport of the MachineFor the transport of the machine only eye bolts type Starpoint VRS of the manufacturer RUD or equivalent products of othe

Page 14

INThe machine has to be installed horizontally on a solid founda-tion and – if necessary - it has to be  xed by means of screws.After the installati

Page 15

INIf the machine has been delivered with a separate hydraulic power unit, it is essential to rinse out the hydraulic system after the install

Page 16 - ATTENTION

INACHTUNG•Auf Drehrichtung des Pumpenmotors achten!•Motor muss in Pfeilrichtung drehen!•Gegebenenfalls Drehrichtung des Motors durch Vertau-schen

Page 17 - Maintenance Recommendation

Abridged operation manual DigiMaxx C-20nSwitch on the machine by actuating the mains switch and then switch on the electronic unit by pressing button

Page 18

Abridged operation manual DigiMaxx C-20nIf necessary you can change the display N/mm² referred to the specimen’s area with button nPress START. The z

Page 19

3000 kNM1+0,00 kN0,00kNsZEROPEAKCALCDATARESD Maxx C-20IGI5SET0DEL.327F049DI8MAESCFNCEX1DE62 DIGIMAXX C-20 Digital

Page 20 - Transport of the Machine

Page 2Table of Contents• General view ...3 • Explanations for the

Page 21 - Installation of the Machine

Page 3• General viewType of device:Real digital control unit which has been developped for all types of testing machines. Expandable to a fully auto

Page 22

• Explanations for the keysDevice on/off Peak value measurement on/off

Page 23 - Sense of the Pump Motor

Manufacturer's dataBATesting machine ALPHA 3-3000Serial numberFORM+TEST Seidner+Co. GmbHZwiefalter Str. 20D-88499 RiedlingenTel. +49 (0) 7371 93

Page 24 - DigiMaxx C-20

• Explanation for the KeysIn case of double displaySelection of measuring parameters with status line at the sueen.This applies to the change -over

Page 25

1 W 15M1+100,0 N/mm²0,00N/mm²sPK ZB BD GD• Explanations for the LCD-displaySelection of measuring parameters:Screen: M

Page 26 - DIGIMAXX C-20

Page 7• Explanations for the LCD-DisplayDouble display: (Option) Control channel

Page 27

Option Move the beam SelectionReport:

Page 28 - • General view

• Sub-menu "Report"The print-out can be started manually or by the break detection. Date and testing number can be set.

Page 29 - • Explanations for the keys

• Print command of print-outThe print-out is automatically started by the break detection.By pressing the DATA key the print-out can be started manu

Page 30 - • Explanation for the Keys

• Sub-menu "testing"Different test courses are possible: A simple ramp function with cycles, a step program and a pro-gram for the E-Modu

Page 31 - 3000,0 kN

• External test (Option)Funktion: ® By pressing START the piston extends, the specimen is being charged and the preselected contro

Page 32 - 100,00 mm

• Sub-menu "Ramp, Cycles"

Page 33 - Selection

• Ramp Programming for Cyclic TestsEntrance from main menu (ramp). Here cyclic test can be programmed, but only for testing in kN (not in N/mm²)•

Page 34

Manufacturer's dataBATesting machine DELTA 5-200Serial numberFORM+TEST Seidner+Co. GmbHZwiefalter Str. 20D-88499 RiedlingenTel. +49 (0) 7371 930

Page 35

Page 15• Automatic Test Course Settings before the test in case of display in N/mm²Break detection BD must be activated. The selection of the speci

Page 36 - Peak : O

• Test course with measuring and weighing1. Select the specimen type with CALC.2. Start the test by pressing START, the measuring screen is invoked.3.

Page 37

Force control and force displayMax. 10 steps Velocity range of a 3000 kN machine:0,001 ...3000 kN/sHolding t

Page 38 - 3000 kN Test

• Programming of Elastic ModulusWith this program the programming of test course for the determination of the elastic modulus confor-ming to standard

Page 39 - r

• Calculation of Elastic ModulusAfter the execution of the ramp which is determining the elastic modulus the value of the elastic modu-lus is printed

Page 40 - Additional Test Courses

Programming of the testSelection of the test type under menu "settings"200 kN TestM1FO 10.000 kN0.200 kN/s5.00 sDE0,500 mm0,005 mm/s0,00 sDI

Page 41

Activation of the adjustment mode in menu "settings" Adjustment: ON/OF

Page 42 - • Step programming

• Sub-menu Settings

Page 43 - holding time

In case of double display the load pacer can be rmly adjusted to force: FO or selection ANW. In case of selection: ANW the parameters FO,DI,DE and EX

Page 44 - E-Modul 32250

• Specimens' conguration / Specimens' memoryUp to 30 specimens are freely congurable. Specimens 1 to 3 are congured by the factory.

Page 45 - 200 kN Test

BAThis document facilitates to get to know your testing machine resp. your testing system (briefly called: machine) and its capa-bilities.The

Page 46 - • Adjustment (Option)

The following inputs are possible: cube stone prism 3-point beam

Page 47 - • Automatic Zeroizing

Page 26• Sub - menu "Calibration"Select sub-menu: factory calibrationSet cursor to calibrationPress ENTERSet the calibration code XXXXSele

Page 48 - • Break Detection

Page 27• LinearisationThe precision of the testing machine can be increased by means of linearisation. If the table is empty, all points have to be

Page 49 - ESC: Abort

• Calibration Table The calibration table contains the values measured during calibration/linearization. Individual values can be corrected by input

Page 50 - *" in front of

ESC : AbortAuto Calib. M11 300.000 kN2 600.000 kN3 900.000 kN4 1.200.000 kN5 1.500.000 kN6 1.800.000 kN7 2.100.000 kN8 2.400.000 kN9 2.700.000 kN10 3.

Page 51 - • Delete cal

• Manual OperationApplicationManual charging with partial or full load, for example for calibration or linearization.Procedure Start the

Page 52 - • Linearisation

• Sub - menu LCD Contrast Setting Selection through main menuBy means of ↑ and ↓ the contrast of the LCD-display can be adjusted in 8 steps for the

Page 53 - • Print-out the Table

• Sub-menu „Measuring / Weighing“ (Option)Starting from the main menu by means of the key ENTER at „measuring / weighing“.The three inputs for meas

Page 54 - • Calibration Values

• A-4-Page printerWith the operation of an A4-page printer the title „TEST RECORD“ is printed and the line counter is reset after pressing the key EN

Page 55 - • Manual Operation

Installation Proteus-e.indd - 1.5 - 03/2007Installation Proteus-e.indd - 1.5 - 03/2007Proteus is a 32 bit application and can therefore be installed o

Page 56 - LCD contrast

BAThe machine is designed for static loading with statical or dyna-mic course. It is designed for compression, bending or tensile tests.For a desig

Page 57 - Dimensions

OPERATING MANUALElectronic Double and Triple Strain Transducers LD DD1-2-3Version 2 17.09.2002 as/la

Page 58 - • Handwheel (Option)

2Electronic Double and Triple Strain Transducers Type LD-DD1-2-3Electronic Double and Triple Strain Transducers Type LD-DD1-2-3for measuring the me

Page 59 - Additional notes:

3Double/Triple strain Transducer at concrete cubeKnurled Screw (1)Connecting rods (2)Knurled Screw (3)locking leverl (4)measuring edge (5)pict. 2: mea

Page 60 - 17.09.2002 as/la

pict. 3: Triple Stain Transducer at concrete cylinderpict. 4: Double and Triple Strain Transducer with accssories4knurled screw (1)connecting rods (2)

Page 61

Functional Description:Functional Description:Double Strain Transducer LD-DD1-2Triple Strain Transducer LD-DD1-3Triple Strain Transducer LD-DD1-31

Page 62 - Dimensions (in mm)

6Example for the Calculation of the Compression-E-ModulusExample for the Calculation of the Compression-E-ModulusGiven:specimen (lxwxh) 40x40x160 mm

Page 64

DistributorYear of construction2007DriveAS-C20-NColour RAL 7032RAL 3002 A1.1 Basic DataInspected byDateDaniel Nacke10.04.2007CustomerServi MotionOrder

Page 65

Type of machine ALPHA 3-3000 Machine no. 026433.000 kNMax. test forceDimensionsframework1.750HeightWidth Depth750 650Dimensionshydraulics2.100650 1.10

Page 66

A2 Hydraulics and Electrical SystemSupply voltageControlControl cabinetElectronic systemMeasuring amplifier belowMeasuring amplifier above3 x 400 V +

Page 67 - Basic Data

BAThe machine has been constructed considering a danger analy-sis and after careful selection of the harmonized standards to be used and of further t

Page 68 - Machine Record Card

A2.1 Hydraulics and Electrical SystemData of sensors/valves M11. Measuring rangeDeformationForce Piston stroke3.0002. Measuring rangekN mmkNmmmm mm3.

Page 69

A2.2 Hydraulics and Electrical SystemData of sensors/valves M2200 kN mmkNmmmm mmkN mm mmkN mm mmM2M2M2M207/1285CTC4-200 KN402795TLH 2250253092X displ

Page 70 - Data of sensors/valves M1

A3.1 FrameworkPressureM3M1 M23000Piston areakNCompression barPiston stroke mmDimensions of test chamberPressure plates above200M4cm²754,38 103,81397,

Page 71 - Data of sensors/valves M2

A3.2 FrameworkGrooved ringM3M1 M2 M4310x6 24X3(2X)105X5Wiper ringO-RingO-RingO-RingO-RingO-RingS90X105,1X6,3 T46N RSSOStepsealO-Ring 105X5Piston seal

Page 72 - Framework

A4 Calibration table0 %M1base table2 %4 %6 %10 %Machine1Measuring rangeM2base table120 %40 %60 %80 %100 %Tare valueCalibration factorValue 0 mV/V - 1

Page 73

A5.1 Factory configuration electronicsFOM3M1 M2CH1FOFODIDIM43000kN100Electronic systemEPROM version DMAX V9.60 SUCYDigiMaxx C20DigiMaxx C20DigiMaxx C

Page 74 - Calibration table

A5.2 Factory configuration electronicsFOM3M1 M215,00 %2 %4 %6 %M48,06,04,010 % 3,030 % 2,060 %80 %4,08,06,05,0 5,04,03,02,01,01,0 1,01,0WE2WE2WE2WE2D

Page 75 - Machine set

KL- FB 07Test CertificateC

Page 76 - Gain set

KL- FB 07Test CertificateC

Page 77 - Test Certificate

Page 1/2Test acc. to DIN 51302 part 2Costumer :Servi MotionOrder No.:07/1285Machine (Typ/Force/No./Year):A

Page 78

BAPlease ensure that only quali ed or trained staff operates the machine. These persons have to know the possible risks of the machine.You sh

Page 79 - Test acc. to DIN 51302 part 2

Page 2/2Costumer : Servi Motion Servi MotionOrder No.: 07/1285Machine: ALPHA 3-3000 , 3000kN , M.Nr.02643

Page 80 - Signature:

EHEMPrüfprotokolltest certificate / orotocole d'essaiTvp:type / typeNennmessbereich: 2,5 mmrange / portöeldentNr:serial no / N'- ident1 0503

Page 81 - Prüfprotokoll

mHEMPrüfprotokolltest certificate / protocole d'essaiTvp:type / typeDD1Auftrag:order no / commissionPrüferexaminer / contröleurDatum:test date /

Page 82

EHEMPrüfprotokolltest certificate / orotocole d'essaiTyp:type / typeDD1Nennmessbereich: 2.5mmrange / porteeldentNr:serial no / No- ident1 0503003

Page 83

12Türe gebrücktPumpeSCHAnlage:DeckblattOrt1 2 3 4 5 6 7 8Ers. durch11.02.2004ZollMagnet, SchlüsselschalterAllgemeinUrspr.C-20, 2 Maschinen, m. Pumpe E

Page 84 - E-3\300E3031-1

L1-X1123456-Q1L2 L3 N PE12-K1/3.2U-X1I> I>I>135246-Q234VM3UVWPE-M1Entstört mit Murr RC 3R56W PE-F110A1314-K1/3.21U-X1NM1PNPE-M2PE1-X1L1 PE N-

Page 85 - Leistungsteil

24V+/2.80V/2.84-X13-X11112-S112/2.234/2.256/2.213 14/2.653 54363 6451314-Q2/2.25-X11112-S21314-S36-X1A1A2-K17-X15354-K12X1X2-H13-X108-X113 14/4.121 22

Page 86 - Steuerungsteil

24V+/3.81-24V+/3.80V/3.81314-K2/3.417-X112-Y13132-K3/3.718-X112-Y24344-K3/3.719-X112-Y313 14/3.621 2233 3443 441314-S820-X2A1A2-K4X1X2-H224V+1-24V+0VD

Page 87

arpptbaY1G3-2R1CPLR-1-5-7ar pA1 A2PparR-4-6M-8-9-10-11-12M-13-14-15OptionOption-2 Y2 -3 Y3OptionSchaltschrankAnlage:HydraulikschemaOrt1 2 3 4 5 6 7 8E

Page 89

BADuring the running the working place of the operating staff is in front of the machine. A working beside or behind the machine can be necessary for

Page 91

BADie Konformitätsbescheinigung zu Ihrer Prüfmaschine wird Ihnen in einer separaten E-Mail zugesandt.The conformity certicate for your test-machine w